1. fotoaparati
  2. Car Audio & Electronics
  3. Home Audio
  4. Osobni Audio
  5. TV
  6. Pametna kuća
  >> Hrvatska Electronic Technology >  >> Pametna kuća >> Usisavač

12 smjernica za rješavanje problema Hoover WindTunnel – uključeni videozapisi

Kad ste koristili Hoover WindTunnel, ponekad ne radi dobro ili prestane raditi. Danas ćemo razgovarati o rješavanju problema Hoover WindTunnela. Pa, prije nego nastavim s tim, moram se vratiti u prošlost.

Jako volim svog psa – čokoladni laboratorij – ali odnedavno je kuća počela smraditi. Možda mi je trebao drugi usisavač da zamijenim usisavač u spremniku.

Budući da sam u određenim godinama, imao sam dugogodišnje iskustvo čišćenja doma. Odrastao sam s kanisterskim usisavačem i koristio sam ga u svom glavnom životu. Ne, nije isti, imao sam više.

Mrzio sam miris iscjetka iz mog sadašnjeg usisavača iako svaki put mijenjam vrećicu i pitao sam se koliko dobro skuplja dlake kućnih ljubimaca.

Malo sam istraživao na Googleu, provjerio s raznim stručnjacima za recenzije i našao sam najbolji usisavač ispod 100 USD.

I – ovaj model Hoover Windtunnel došao je kao spasitelj i ne prevelika cijena. Pa iako smatram da ulaganje pristojnog novca za dobar uređaj obično nije loša strategija.

Ovaj Hoover WindTunnel očistio je moje deke i tepihe kao da nisu prani godinama i preko noći je moja kuća bolje mirisala. Moje su prostirke bile svjetlije i ugodne. Stvarno - podiglo je masu. Sretan sam, u najmanju ruku, i voljan sam izraziti njegove loše stvari sve dok mi čisti kuću.

Kad ste koristili Hoover WindTunnel, ponekad ne radi dobro ili prestane raditi.

Danas ćemo riješiti ovaj problem.

12 najvažnijih smjernica

Ovo je jedan od najčešćih problema Hoover WindTunnela. Razlozi problema navedeni su u nastavku.

Provjerite začepljenja

Najprije provjerite svjetlo indikatora učinkovitosti, kada postane crveno, to obično znači da je nešto začepilo vaš usisivač.

Dakle, radi se o začepljenju koje uzrokuje isključivanje usisavača.

Skinite crijevo s oba kraja i provjerite sve. Uzmi dršku metle očistite ga štapom kako biste izbacili sve što bi moglo biti zaglavljeno.

Zatim skinite poklopac s mlaznice i provjerite donje crijevo.

Ako nije radio kako treba, mogao bi biti začepljen filtar da biste to provjerili, uklonite posudu za prljavštinu i podignite filter.

Morate očistiti njegovu prašinu i isprati jednu ili dvije minute pod toplom vodom i morat ćete je pustiti da se suši cijeli dan.

Provjerite valjak četke

Provjerite valjku četke za WindTunnel . Ako se vaš kist ne okreće, još jednom provjerite način rada za prebacivanje kako biste bili sigurni da niste u načinu rada samo na početku.

Ako postoji bilo kakva blokada ili dlaka, uzmite nož kako biste zarezali uzduž ovog valjka četke i skinite svu suvišnu kosu s oblika.

Lako ćete to učiniti, samo trebate skinuti vijke na podnoj ploči kako biste skinuli podnu ploču sa stroja i zamijenili najbolje. To je sve što morate učiniti za održavanje.

Ovaj remen možete pronaći na većini mjesta i to bi trebalo riješiti vaš problem.

Većina slučajeva zaglavljene šipke četke lako se čisti, morate jednostavno povući ostatke iz šipke četke.

Ali u nekim vakuumima ova metoda ne radi ispravno. Ako trebate očistiti problematičnu blokadu kao što je Dyson četka koja se ne okreće, možete lako izvaditi četku iz kućišta za brzo održavanje.

Čišćenje filtera

WindTunnel ima dva filtera. Primarni filtar treba čistiti svaka dva mjeseca prema potrebi.

Konačno, ako i dalje imate problema, provjerite HEPA filtar tako da ga izvučete, a ako je filtar jako prljav ili istrošen, trebali biste ga očistiti.

Možete naručiti zamjenski filtar za oko 10 USD na službenoj web stranici Hooversa, možete ga pronaći na Amazonu.

Ako imate drugih problema s usisavačem, trebali biste nazvati službu za korisnike. Za ovaj stroj imate ograničeno jamstvo od 2 godine.

Evo vam jednostavnog rješenja, kada vaš WindTunnel izgubi snagu usisavanja. Obično uzrokuje začepljenja.

Evo što prvo trebate učiniti, provjerite svjetlo indikatora na vrhu vaše čaše za prljavštinu . Ako je crveno nešto ograničava protok zraka.

Ovdje smo razgovarali o tome kako to možete popraviti.

Najprije uklonite posudicu za prljavštinu, otvorite je i provjerite filter.

Provjerite donju stranu ako je prljava, isperite je toplom vodom i ostavite 24 sata da se osuši.

Pazite da ga postavite na rub kako bi se ravnomjerno osušio. Čak i ako ga redovito ispirete, postavljanje filtra koji se ne u potpunosti vraća u posudicu za prljavštinu moglo bi još lakše začepiti filtar.

Zatim provjerite je li glavno crijevo začepljeno. Trebali biste ga ukloniti sa stroja i drškom metle izbaciti sve ostatke koji su tamo zapeli.

Sada postoji još jedno mjesto koje možete provjeriti. Ako su ta dva jasna, a još uvijek nemate jak usis.

Uklonite poklopac, a zatim izvadite valjku četke i sada provjerite ima li začepljenja u donjem crijevu.

Možete koristiti alat za hvatanje da otkloni sve začepljenja.

Alat Grabber važan je alat koji trebate prije nego što se upustite u rješavanje sličnih problema poput resetiranja vakuumskog motora Shark. Provjerite imate li ih prije nego počnete rješavati probleme.

Sada sve o vodičima za popravak samohodnih motora WindTunnel.

Ako je vaše poteze teško pritisnuti, provjerite je li samohodni gumb uključen.

Ako ne vidite odmah poboljšanje, ručka je možda previše labava.

To je jednostavno rješenje, prvo isključite i odspojite svoj Hoover. Zatim uklonite vijke sa stražnje strane ručke.

Provjerite jesu li samohodni prekidač i prekidač za napajanje isključeni na ručki.

Također provjerite je li prekidač napajanja na kućištu stroja postavljen na isključeno.

Zatim umetnite ručku natrag u jedinicu i čvrsto je zavrnite. Sada ga uključite, gurnite prekidač za uključivanje i uključite samohodnu značajku.

Na kraju o podešavanju visine. Najprije morate početi s najvišom postavkom.

Zatim radite prema dolje dok ne čujete kako čekinje valjka četke dodiruju tepih i osjetite kako usisivač glatko klizi po tepihu.

Čišćenje vaših filtara pomoći će da vaš WindTunnel usisivač radi na vrhunskoj učinkovitosti.

Postoje dva filtra od kojih primarni treba čistiti svaka dva mjeseca ili po potrebi, a HEPA filtre treba čistiti svakih šest mjeseci za optimalne performanse.

Za početak stavite čistač u uspravan položaj. Isključite napajanje i izvucite utikač iz utičnice.

Uklonite posudu za prljavštinu iz usisivača i okrenite poklopac da se otvori. Zatim uklonite filtar koji se može ispirati i ispirite vodom dvije minute ili dok voda ne postane bistra, iscijedite višak vode i ostavite da se suši najmanje 24 sata.

Nikada nemojte vraćati mokri filtar koji se može ispirati u usisivač. Nakon što se potpuno osuši, zamijenite filtar i okrenite poklopac posude za prljavštinu da biste je zatvorili.

Drugi filter je HEPA filter. Možete ga pronaći na vrhu osnovne ploče, da ga očistite i izvučete van.

Ne perite ovaj filtar vodom, jednostavno dodirnite filtar o unutrašnjost kante za smeće kako biste izbacili prljavštinu i ostatke.

Zamijenite filtar i uvjerite se da čujete da je škljocnuo na mjesto, za zamjenu filtara koristite samo ovlaštene Hoover dijelove.

Najprije morate ukloniti HEPA filter izvlačenjem plastičnog okvira filtera. Filtar treba čistiti samo tapkanjem i nemojte prati niti ispirati HEPA filtar.

Nakon tapkanja filtra za čišćenje jednostavno ponovno umetnite okvir filtra natrag u Hoover bazu dok ne klikne.

Imajte na umu da kada se pravilno koristi i održava, HEPA filtar ne treba mijenjati unutar jamstvenog roka.

If a replacement is needed to be sure to get the Hoover HEPA filter designed for your vacuum.

Hoover WindTunnel repairs will require you to disassemble the product before you attempt this make sure the power cord is unplugged.

To access the belt or brush roll you will need to remove the bottom plate.

The plate may be secured by screws or by latches remove the screws or slide the latches out of the way and pull the plate off.

Then you should pull out the brush roll and detach it from the belt if necessary.

When the repair is complete first loop the belt around the brush roll and aligns the tabs on the sides of the roll with the notches in the frame.

Then reposition the bottom plate and secure the latches or screws. To access the start switch first remove the upper filter assembly.

Now remove the screw to release the handle assembly.

Remove the screws holding the handle assembly together use a small flat-head screwdriver to detach the hinge caps.

Now remove the bolt and remove the hinge screws to separate the two halves of the handle assembly.

When the repair is complete join the two halves of the handle assembly together.

Replace the hinge screws then insert and secure the bolt. Snap-on the hinge caps. Reinstall the rest of the handle assembly screws and slide the handle into position.

Secure the screw and snap the upper filter assembly into place.

If applicable to your model you can access the rewind cord housing and motor assembly by first removing the HEPA filter.

Now lift off the upper filter assembly and remove the screws to release the cord housing plate.

Your next step is to remove the hose.

Now uninstall the screws to release the hose fitting remove the screws securing the vacuum cleaners back panel and any guides or supports.

Then pull the panel off.

Remove the screws securing the hinge covers and unclip both covers.

Now unhook the belt from the motor shaft and lift the handle cord reel and motor assembly of the base.

Remove the screws securing the motor housing pull off the retaining clip if necessary and separate the housing.

If required you can now remove all of the screws securing the cord housing cover.

When the repair is complete reinstall the cord housing cover and secures the screws.

Join together the two halves of the motor housing. Snap the retaining clip into place if necessary and replace the screws to secure.

Now align the motor housing with the base and hook the belt onto the motor shaft.

Snap the hinge covers into place and replace the screws to secure. Next, reposition the back panel as well as any guides or supports and secure them with the screws.

Realign the hose fitting and secure the screws, reattach the hose replace the cord housing plate and reinstall the screws to secure.

Reposition the upper filter assembly and reinsert the HEPA filter with the vacuum cleaner fully reassembled you should test the product to make sure it’s functioning properly.

The main pieces to your WindTunnel Hoover are.

  • The vacuum base
  • The handle
  • The dirt cup
  • Extension tube
  • Crevice tool
  • Upholstery tool
  • An air-powered turbine hand tool

To assemble first remove the main screw from the handle base.

Slide the handle into the vacuum base push down firmly and tighten the screw with a Philips screwdriver.

Attach the dirt cup by sliding it in. Attach your tool so you’ll be able to easily reach for them. When you need them to put the air-powered turbo tool on the handle.

Slide the crevice tool into the extension tube and place it on the left side of the cleaner and the upholstery tool goes on the right side.

Set the hose onto the carriage. There is an automatic cord rewind feature that lets you pull out and rewind the power cord to need easy storage.

Your cleaner is now fully assembled and ready to use. A few things to keep your WindTunnel to rewind running well.

There are two filters the primary should be cleaned every two months or as needed and the HEPA filter should be cleaned every six months.

You will need to keep your brush roll clear of thread pet hair and other debris. See the maintenance and troubleshooting topic for more detailed guidance.

Hoover WindTunnel has some pro feature and innovative technology like

  • Automatic rewind cord
  • Five-position adjustment
  • Easy maintenance filter
  • Other accessories

Automatic rewind cord

Hoover WindTunnel holds 27 feet rewind power cord and that is very enough long to clean any large space and it doesn’t need to plug out and replug the power cord.

Five-position adjustment

Five-position adjustment of Hoover one of the innovative technology. This five-position adjustment very effective to clean all types of floors and surfaces.

Easy maintenance filter

This WindTunnel represents a bagless technology and it maintains optimal suction power. It has a rinsable filter that can be cleaned with warm water. It also has a high-quality HEPA filter.

Other accessories

  • Comfortable grip handle
  • Fingertip nozzle
  • Thirteen and a half-inch wide nozzle
  • No-scuff bumper
  • 12-inch extension wand
  • A crevice tool

We sometimes hear from you guys that your WindTunnel is overheating and shutting off. This can happen when there’s a clog somewhere in the system.

On some of the versions of the vacuums, you might hear a whistling or hissing sound when your vacuum is on the verge of shutting off.

That’s the system performance indicator. First, turn the vacuum off and remove the dirt cup.

Take the lid off and inspect the filter, if it’s dirty.

Rinse it with warm water for two minutes and let it dry for at least 24 hours.

Your vacuum also contains a HEPA filter. Take the cover off and check this filter.

If it’s dirty. Don’t get it wet instead, tap it into a wastebasket.

Next release the hose by pressing green clip.

It’s on most versions of the WindTunnel and sees if there are any blockages inside of it.

You can use a wooden spoon handle or another household object. Just don’t use anything sharp that could damage your hose.

Lastly, leave your vacuum turned off for about half an hour.

The thermal protector that activated the shut-off will deactivate.

You can start cleaning again. These tips should get your WindTunnel in great working.

I’ll be showing you, how to replace a Hoover WindTunnel power cord.

The power cuts out, then do check the main cable, with the cable still plugged in and the machine running give the wire a wiggle around. If the power cuts on and off either at the plugins or at the machine end, then the cable has failed and it needs replacing.

Safety first! Always unplug an appliance before carrying out any work.

I’ll be doing this fix on this Hoover vacuum cleaner.

The process should be quite similar to your make and model.

To access the mains cable, I need to first remove the underneath of the vacuum cleaner by undoing the screws that hold it in place.

To access where the cables are going, the mains cable comes directly into the machine.

Wires go underneath this cover. I’m going to remove this cover by undoing the two screws that hold it in place.

If the motor cover removed, we can see the cable clamp that holds the main cable in place.

To release cable, I’m just going to take a pair of pliers and pinch the two tabs should release the mains cable from the back of the machine.

Then you can just use a screwdriver just to push the wire down.

The mains cable released.

I forget to give it a little pull. I can tell which wires are connected inside, if I just pull these wires out as well you can see that more clearly.

It’s the blue and the brown here that are connected inside the mains cable.

What I want to do, because these the blue has been crimped here and I don’t want to disturb the brown wire that goes to the switch.

There is a little bit of space next to the motor, where I can put a terminal block and connect the new wires from the new mains cable to the old wires inside the machine.

The new mains cable does not come with any connection.

I’ll be using this electrical terminal block to connect the wires.

I’m going to snip the brown and the blue wire. Then feed those out by the old mains cable. I’ll just cut those cables now.

I’m also going to do is just strip back the insulation to expose the copper inside.

Then give a nice twist. It looks nice and solid and then just fold it back on itself, that it will fit nice and firmly inside the terminal block.

I’ll do exactly the same with the brown one.

I can then remove the mains cable from the vacuum cleaner.

Now the old cable is out of the way. I can grab my new one. Now what I’ve done is pre-stripped down the insulation. It gives me enough space to feed the wires under the motor.  Of course, connect blue to blue and brown to brown using the terminal block.

It’s worth pointing out that the new mains cable. The two ends have been crimped already. So, I don’t have to prepare those.

You can use a terminal block to connect the wires up.

With the wires all wired up nicely in the terminal block. I’m just going to push them down the side of the motor.

I need to do is to replace the old clamps that were on the old mains cable and put them on the new one.

The clamp-on your model may take a little bit of squeezing to get it into position. So, I’m just using a pair of pliers to do that on this one.

With the mains cable now in position. I can replace the motor cover. I’m just going to make sure there are no wires in the position of the screw holes. So, they’re not being pinched by the motor cover.

Lastly, now I can replace the base.

We have it one brand new mains cable fitted to this Hoover vacuum cleaner.

It has been having problems with, my Hoover vacuum cleaner switch.

I’ve decided to replace it.

This is a Hoover WindTunnel.

To replace the switch, remove the attachment.

Just connect hose again.

I’m going to remove screws from Handel.

Remove the canister.

Once you have that out, you can remove that holds the switch.

Once that’s done remove the two screws on the bottom and separate the unit using just a standard screwdriver.

I’ve got my unit apart here and see here is the link between the vacuum cleaner and the switch.

There’s your switch and there’s your link, at this point you’re going to just connect those two electrical contacts.

Remove the switch and pull it out. I was able to kind of pull it out with my bare hands.

I’m going to disconnect these two wires take the switch out of this housing.

You can see the housing that holds the switch has those two little clips on it.

I’m going to take a screwdriver, stick it under there and remove the switch from the Hoover housing.

So, you can see I’m about to take this switch out of here.

Let’s go and push up on it.

Take my new switch. Put it in the housing.

Put your switch back in the vacuum cleaner.

You have it reroute your wires screw everything back together be good to go.

I’m going to take apart or don’t get you.

Just steps there back together make sure that your peace doesn’t fall into the wrong orientation as you close it.

Just make sure this you have put all your screws back in and you’ve got a functioning switch.

Today we’re going to change the filters on the Hoover self-propelled WindTunnel vacuum cleaner.

  • First, make sure that your vacuum is unplugged out of the wall.
  • Click the switch and lay vacuum down.
  • Lay your vacuum down on a raised surface such as a table.
  • Remove the top sole plate first.
  • Take out the bag.
  • Take out the filter cover.
  • Replaces the old filter.
  • Take the cover motor filter cover put that on top.
  • Replace your final filter for this vacuum.
  • Take out the old filter.
  • Replace it with your new vacuum filter.
  • Replace your bag.
  • Pop the top back on.

Final Sentences

Hoover WindTunnel gets four-star up with positive reviews in different marketplaces. Hoover WindTunnel is easy to move, simple maneuverability. You can get optimal suction power from it.

Your Hoover WindTunnel is your most precious cleaning partner and it cleans different types of surfaces like hardwood floors or carpet.

Sometimes your Hoover WindTunnel needs troubleshooting. Here we have solved all Hoover WindTunnel possible problems. If you have a Bissell vacuum and experiencing any difficulty with this, then you can also read our Bissell Proheat troubleshooting guideline.


  1. Sony Subwoofer problema
  2. Kako provjeriti telefonskog red za AT & T
  3. Rješavanje problema Bump za Android
  4. JVC prijemnik problema
  5. Kazetofon problema